AMERICAN GREASE STICK CO -- RUGLYDE, RG-20 -- 6850-00N015498
=====================  Product Identification  =====================

Product ID:RUGLYDE, RG-20
MSDS Date:02/25/1988
FSC:6850
NIIN:00N015498
=== Responsible Party ===
Company Name:AMERICAN GREASE STICK CO
Address:2651 HOYT STREET
City:MUSKEGON HEIGHTS
State:MI
ZIP:49444
Country:US
Info Phone Num:800-253-0403; 616-733-2101
Emergency Phone Num:800-253-0403; 616-733-2101
Preparer's Name:CHARLES HIDDEMA
CAGE:EO473
=== Contractor Identification ===
Company Name:AMERICAN GREASE STICK CO DBA AGS
Address:2651 HOYT ST
Box:729
City:MUSKEGON
State:MI
ZIP:49443
Country:US
Phone:231-733-2101; 800-253-0403
CAGE:96980
Company Name:AMERICAN GREASE STICK COMPANY
Address:2651 HOYT STREET
Box:729
City:MUSKEGON HTS.
State:MI
ZIP:49444
Phone:(800) 253-0403
CAGE:EO473

=============  Composition/Information on Ingredients  =============

Ingred Name:POTASSIUM VEGETABLE OIL SOAP
Fraction by Wt: 5-15%

Ingred Name:ETHYLENE GLYCOL  (SARA III)
CAS:107-21-1
RTECS #:KW2975000
Fraction by Wt: 1-5%
OSHA PEL:C 50 PPM
ACGIH TLV:C 50 PPM,VAPOR; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: MAY CAUSE IRRITATION,
    DISCOMFORT & PAIN. SKIN: MAY CAUSE IRRITATION/DERMATITIS. INHAL:
    MAY CAUSE IRRITATION. INGEST: MAY CAUSE NAUSEA AND/OR DIARRHEA;
    DEPRESSION FOLLOWED BY RESPIRATORY C ARDIAC FAILURE; RENAL & BRAIN
    DAMAGE. CHRONIC: VAPORIZING SOLUTION MAY CAUSE INHALATION EFFECTS
    (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: SUCH AS CNS DEPRESSION AND
    HEMATOPOIETIC DYSFUNCTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. GET MEDICAL
    ATTENTION. SKIN: WASH AFFECTED AREA. REMOVE CONTAMINATED CLOTHING.
    IF ADVERSE EFFECTS OCCUR, CONSULT A PHYSICIAN. INGEST: INDUCE
    VOMITING. G ET MEDICAL ATTENTION. INHAL: REMOVE TO FRESH AIR. GIVE
    OXYGEN OR ARTIFICIAL RESPIRATION AS REQUIRED, CONSULT A PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ABSORB ON INERT MATERIAL. FLUSH RESIDUE WITH
    WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NONE KNOWN.
Other Precautions:NONE KNOWN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NORMALLY NEEDED.
Ventilation:GENERAL ROOM VENTILATION IS SUFFICIENT.
Protective Gloves:RUBBER OR PLASTIC COATED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH IN AREA.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:200F,93C
Vapor Density:> 1
Spec Gravity:1.01 @ 15.5C
pH:9.6
Solubility in Water:COMPLETE
Appearance and Odor:AMBER LIQUID WITH CHARACTERISTIC ODOR.
Percent Volatiles by Volume:90(WT)

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO*X.

====================  Disposal Considerations  ====================

Waste Disposal Methods:NOT DETERMINED. REMOVAL BY AN APPROVED, LICENSED
    WASTE HAULER. DISPOSAL MUST BE IN ACCORDANCE WITH LOCAL, STATE AND
    FEDERAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.